Skip to content
Sci Adv·· 21 hours agoPickScore75

High ambipolar mobility fluorinated MXene for ultrasensitive biosensing transistors.

In brief

An in-situ fluorinated MXene biosensing platform achieved a detection limit of 0.26 fg ml-1 for Mycobacterium tuberculosis antigen MPT64 in an MXene FET, and reached 97.6% diagnostic accuracy across 126 serum samples.

Deep dive

As a two-dimensional transition metal carbide, MXene has long been regarded as an ideal material for biosensing owing to its metallic conductivity and solution processability [1], while its surface, rich in terminal groups such as -F, -OH, and -O, further endows it with designable electronic structures and physicochemical properties [2][3]. Field-effect transistor (FET) architectures can directly convert biological recognition events into electrical signals, enabling real-time label-free detection; however, the intrinsic zero band gap of pristine Ti₃C₂Tₓ results in an extremely low on/off ratio (only about 1.02), making effective signal modulation difficult. Meanwhile, in aqueous environments the -OH terminations readily trigger hydrolytic oxidation, destroying the conductive framework and introducing interfacial noise, severely limiting practical deployment in physiological settings. To address these two bottlenecks, this work proposes a synergistic strategy of in-situ fluorination and gate functionalization: increasing the LiF molar ratio during the etching synthesis stage exploits Le Chatelier's principle to drive the termination equilibrium toward Ti-F bonds, yielding highly fluorine-covered F-MXene (Ti₃C₂(OH)₀.₁F₁.₆₈O₀.₂₂) in a one-step process; fluorine termination confers a weakly hydrophilic, chemically inert interface that suppresses oxidation and reshapes the electronic states near the Fermi level, while the gate-functionalization architecture physically separates the recognition units from the transport channel, preserving the channel's electrical integrity. The high electronegativity of fluorine increases the electric double-layer thickness, lowers the interfacial capacitance, and amplifies the effective gate-voltage division, thereby significantly enhancing the biogating response.

Materials characterization shows that F-MXene retains the accordion-like layered structure with an interlayer spacing of 1.7 nm (TEM); the XRD (002) peak shifts to a lower angle of 7.8°, but the expansion is smaller than that of hydrophilic MXene, suggesting that fluorine termination suppresses water intercalation. Raman peak shifts corroborate the substitution of -OH by -F; XPS confirms a dominant F 1s peak and a marked attenuation of the O 1s signal; SR-GIWAXS yields a sharp (002) peak (3.09°, d≈10.9 Å), confirming compact layer ordering. In electrical tests, pristine MXene exhibits metallic transport (conductivity 1.362×10⁴ S cm⁻¹), whereas F-MXene displays clear V-shaped ambipolar transport with a charge neutrality point (CNP) of 0.02 V and an on/off ratio of 15.25; the further-optimized FF-MXene sets a new record for MXene transistors, with hole/electron mobilities reaching 10.42 and 30.23 cm² V⁻¹ s⁻¹, respectively, and good reproducibility across three device batches (μₚ 9.60–10.42, μₙ 18.10–30.23 cm² V⁻¹ s⁻¹). However, biosensing performance depends on the normalized transconductance efficiency |gₘ/I_ds|, where F-MXene (118.81 V⁻¹) far exceeds FF-MXene (1.59 V⁻¹), a 74.7-fold gain; combined with its higher on/off ratio and lower CNP, F-MXene was ultimately selected to construct the immunosensor. After oriented immobilization of anti-MPT64 antibodies on the gate via Protein A, the stepwise decrease in output current directly corroborates the biogating mechanism; blinded clinical serum validation confirmed ultrasensitive detection of the Mycobacterium tuberculosis antigen MPT64 with high diagnostic accuracy. Electrochemical aptasensors have previously achieved MPT64 detection [4][5], but this platform combines label-free, real-time operation, high mobility, and blinded clinical validation, advancing MXene FETs toward practical aqueous-phase biodiagnostics.

This work establishes a co-design paradigm coupling high-quality fluorinated MXene with high-performance electronic devices, resolving the core contradiction between the low on/off ratio and aqueous instability of metallic MXene, and achieving a balance between device-level mobility and biosensing sensitivity. Limitations remain: batch-to-batch CNP fluctuations suggest that random distribution of surface terminations leads to variations in local electronic structure; a trade-off exists between absolute mobility and transconductance efficiency, with FF-MXene exhibiting higher mobility but lower sensing performance; and long-term stability in complex physiological matrices, multichannel integration, and multiplexed detection capability still await systematic evaluation.

Why it matters

Termination stability and electric double-layer capacitance constrain MXene signal transduction; in-situ fluorination offers a design path balancing mobility and sensitivity.

Source: Sci Adv · doi.org

CBACBA Frontier Insights (CFI)Chinese Biopharmaceutical Association (CBA)www.cba-usa.org

Disclaimer CBA Frontier Insights uses AI-assisted methods to aggregate, summarize, and analyze publicly accessible biopharmaceutical information. Content is provided for informational and educational purposes only and does not represent the official views of original sources or affiliated organizations. AI-generated content may contain errors; please verify important information against primary sources. Intellectual property rights remain with their respective owners. For copyright concerns or corrections, please contact us through the website’s feedback page.